Armored thermocouple

  • Micro armored thermocouple
Micro armored thermocouple

Micro armored thermocouple

  • Model: WRE-191S, WRN-191S
  • Graduation: K,E
  • Range of temperature: 0~600, 0~400
  • Thermal response time: <3S
  • Description: Micro armored thermocouple is suitable for temperature measurement and control insmall and curved areas.
  • INQUIRY   EMAIL

Micro armored thermocouple


Application of Micro armored thermocouple

It is suitable for temperature measurement and control insmall and curved areas. It is a indispensable temperatureme a s u r i n g d e v i c e i n c h e m i c a l , c h e m i c a l f i b e r,pharmaceutical and other industries


Main tech data of Micro armored thermocouple

Accuracy class: class I or II
Nominal diameter: Φ one
Bending diameter: R ≥ 5D
Nominal pressure: normal pressure
It can be made into insulation type


Model and specification of Micro armored thermocouple

Model

Graduation

Range of temperature

Thermal response time

Material for protective tube

Specification

WRN-191S

K

0~600

<3S

1Cr18Ni9Ti

100*800

200*800

300*800

500*800

750*800

WRE-191S

E

0~400


1. Homogeneous conductor law
A closed loop is formed by welding two ends of the same homogeneous material (conductor or semiconductor). No matter how the conductor cross section and temperature distribution, no contact potential will be generated, the thermoelectric potential will offset, and the total potential in the loop will be zero.


2. Law of intermediate conductor
The intermediate conductor (the third conductor) is connected to the thermocouple circuit. As long as the temperature at both ends of the intermediate conductor is the same, the introduction of the intermediate conductor has no effect on the total potential of the thermocouple circuit, which is the intermediate conductor law.


3. Law of intermediate temperature
The thermoelectric potential between the two contacts (temperature T, t0) of the thermocouple circuit is equal to the algebraic sum of the thermoelectric potential of the thermocouple when the temperature is t, TN and the thermoelectric potential when the temperature is TN, t0. TN is the intermediate temperature.


4. Law of reference electrode
This law is only studied and concerned by professionals. Generally, people in production and use do not understand it. The simple explanation is: use high-purity platinum wire as standard electrode. Suppose that the positive and negative electrodes of nickel chromium nickel chromium thermocouple are paired with the standard electrode respectively, and the sum of their values is equal to the value of this nickel chromium nickel chromium thermocouple.


Ordering instructions
1. indicate the thermocouple model, graduation and temperature range.
2. thermocouple protection tube diameter, length, material, etc.
3. if there are fasteners and flange devices, relevant dimensions shall be provided


Inquiry:

Categories

CONTACT US

Contact: Kevin

Phone: +8615189522935

Tel: +86-517-86800063

Whatsapp: +8615189522935

Email: sales@xfmeter.com