WRR2-120 WRR2-121 Platinum-rhodium thermocouple
Overview
WRR2-120 WRR2-121 Platinum-rhodium thermocouple as a sensor for measuring temperature, usually used in conjunction with display instruments, recording instruments, electronic computers, etc. Directly measure the temperature of liquid, steam and gas medium and solid surface in the range of 0℃-1600℃ in various production processes. It is widely used in the measurement of high temperature in various production processes, such as glass, ceramics and industrial salt bath furnace. Its long-term working temperature is 1600 ℃, and short-term use can measure the temperature of 1800℃. Platinum rhodium thermocouple is also called high temperature precious metal thermocouple, platinum rhodium has single platinum rhodium and double platinum rhodium.
Working Principle
WRR2-120 WRR2-121 Platinum-rhodium thermocouple is formed by connecting two ends of two different conductors into a circuit. When the temperature of the two junctions is different, a thermal current will be generated in the circuit. If there is a temperature difference between the working end and the reference end of the thermocouple, the display instrument will indicate the temperature value corresponding to the thermoelectric potential generated by the thermocouple.
Features
1, Advantage:
Platinum and rhodium thermocouples have the advantages of accuracy, stability, wide temperature range, long service life, and high temperature limit in the thermocouple series. It is suitable for oxidizing and inert atmosphere, and can also be used in vacuum for a short time, but it is not suitable for reducing atmosphere or atmosphere containing metal or non-metal vapor.
2, Disadvantage:
The shortcomings of platinum-rhodium thermocouples are thermoelectric potential, the thermoelectric potential rate is small, the sensitivity reading is low, the mechanical strength decreases at high temperature, it is very sensitive to pollution, and the precious metal materials are expensive, so the one-time investment is large.
Main tech data
1,The diameter of the even wire is specified as 0.5mm, and the allowable deviation is -0.015mm
2,Measuring range:0-1600℃
3,With ceramic end
4,Generally flanged
Note: Any special design or question of WRR2-120 WRR2-121 Platinum-rhodium thermocouple,kindly contact the manufacturer for more details.
Contact: Kevin
Phone: +8615189522935
Tel: +86-517-86800063
Whatsapp: +8615189522935
Email: sales@xfmeter.com
Add: No.118 HengyangNanRoad, Jinhu County, Huaian,Jiangsu, China
We chat