Assembly thermocouple

  • Movable flange thermocouple
Movable flange thermocouple

Movable flange thermocouple

  • Graduation: N,K, E, T,J
  • Range: 0-800 0-1100
  • Thermal response time: <90s <24s
  • Diameter: 16,20mm
  • Description: The Movable flange thermocouple is a commonly used temperature measuring element in temperature measuring instruments
  • INQUIRY   EMAIL

Movable flange thermocouple


The Movable flange thermocouple is a commonly used temperature measuring element in temperature measuring instruments. The movable flange assembled thermocouple produced by Jiangsu Xunfei instrument can directly measure the temperature of liquid, gas, steam and solid surfaces in the range of 0 ℃ ~ 1000 ℃ in various industrial production processes, convert the temperature signal into thermoelectric EMF signal, and convert it into the temperature of the measured medium through secondary instruments. In practical applications, thermocouples have many structural ways, but their working principles are the same. Because of their simple structure, convenient manufacturing, wide temperature measurement range, high precision, small inertia and convenient remote transmission of output signals, they are widely used in industrial production.

Product technical parameters of Movable flange thermocouple
◆ measurement range: 0-800-1000 ℃
◆ accuracy level: Level I (± 1.5 ℃ or ± 0.004 t |) level II (± 2.5 ℃ or ± 0.0075 t |)
◆ thermocouple type: nickel silicon nickel silicon
◆ junction box type: waterproof junction box
◆ installation method: movable flange type
◆ diameter of protective tube: 16mm, 20mm
◆ protective tube material: stainless steel 304, 321, 316, 2520, etc
◆ insertion depth of protective tube: l=150-1800mm
◆ thermal response time: t0.5<80s (when the temperature changes in steps, the output of the thermocouple changes to 50% of the change, the time required is called thermal response time, which is expressed by t0.5)
◆ nominal pressure of thermocouple: normal pressure (generally refers to the static external pressure that the protective tube can withstand without cracking at room temperature)
◆ nominal flow rate of thermocouple: 0 m / S
◆ insulation resistance of thermocouple: the test voltage of insulation resistance at room temperature is DC 500V ± 50V, the atmospheric conditions are temperature 15~35 ℃, relative humidity 45%, atmospheric pressure 86~106kpa, and its insulation value at room temperature should be ≥ 100m Ω.
◆ executive standard: jb/t9238-1999

Product working principle of Movable flange thermocouple
When there are two different conductors, and their two ends are welded with each other, the temperature at the two nodes is different. The temperature at one end is the measuring end or working end, and the temperature at the other end is the free end or cold end. When there is a temperature difference between the two ends, thermal current will be generated in the loop. Equipped with a display instrument, the instrument can display the corresponding temperature value of the thermoelectric EMF generated by the thermocouple. The thermoelectric EMF of the thermocouple will increase with the temperature rise at the measuring end or working end. The size of the thermoelectric EMF of the thermocouple is only related to the conductor material and the temperature difference at both ends, and has nothing to do with the length and diameter of the conductor.


Model example of Movable flange thermocouple

WRN-330 refers to the assembled thermocouple with K-index movable flange, waterproof junction box and protective tube diameter of 16mm, which can be double.
WRE-330 refers to an assembled thermocouple with e-graduation movable flange, waterproof junction box and protective tube diameter of 16mm, which can be double.
WRN-320 refers to the assembled thermocouple with K-index movable flange, splash proof junction box and protective tube diameter of 16mm, which can be double.
WRE-320 refers to an assembled thermocouple with e-graduation movable flange, splash proof junction box and protective tube diameter of 16mm, which can be double.

Product installation picture of Movable flange thermocouple

Model selecting


Model

Graduation

Range of temperature

Thermal response time

Material of tube

Diameter

Length

WRM-330 WRM2-330

N

0~800

0~1100

90s

24s

1Cr18Ni9Ti

0Cr25Ni20

Φ16

150 200 250 300 350 400 500 750 1000 1500 2000 2150

WRM-330G WRM2-330G

WRN-330 WRN2-330

K

0~800

0~1100

90s

24s

1Cr18Ni9Ti

0Cr25Ni20

WRN-330G WRN2-330G

WRE-330 WRE2-330

E

0~800

90s

24s

1Cr18Ni9Ti

WRE-330G WRE2-330G

WRC-330 WRC2-330

T

0~350

90s

24s

1Cr18Ni9Ti

WRC-330G WRC2-330G

WRF-330 WRF2-330

J

0~600

90s

24s

1Cr18Ni9Ti

WRF-330G WRF2-330G

WRM-331 WRM2-331

N

0~800

0~1100

90s

24s

1Cr18Ni9Ti

0Cr25Ni20

Φ20

WRM-331G WRM2-331G

WRN-331 WRN2-331

K

0~800

0~1100

120s

24s

1Cr18Ni9Ti

0Cr25Ni20

WRN-331G WRN2-331G

WRE-331 WRE2-231

E

0~800

120s

24s

1Cr18Ni9Ti

WRE-331G WRE2-231G

WRC-331 WRC2-231

T

0~350

120s

24s

1Cr18Ni9Ti

WRC-331G WRC2-231G

WRF-331 WRF2-231

J

0~600

120s

24s

1Cr18Ni9Ti

WRF-331G WRF2-231G


Inquiry:

Categories

CONTACT US

Contact: Kevin

Phone: +8615189522935

Tel: +86-517-86800063

Whatsapp: +8615189522935

Email: sales@xfmeter.com