Movable flange thermocouple
The Movable flange thermocouple is a commonly used temperature measuring element in temperature measuring instruments. The movable flange assembled thermocouple produced by Jiangsu Xunfei instrument can directly measure the temperature of liquid, gas, steam and solid surfaces in the range of 0 ℃ ~ 1000 ℃ in various industrial production processes, convert the temperature signal into thermoelectric EMF signal, and convert it into the temperature of the measured medium through secondary instruments. In practical applications, thermocouples have many structural ways, but their working principles are the same. Because of their simple structure, convenient manufacturing, wide temperature measurement range, high precision, small inertia and convenient remote transmission of output signals, they are widely used in industrial production.
Product technical parameters of Movable flange thermocouple
◆ measurement range: 0-800-1000 ℃
◆ accuracy level: Level I (± 1.5 ℃ or ± 0.004 t |) level II (± 2.5 ℃ or ± 0.0075 t |)
◆ thermocouple type: nickel silicon nickel silicon
◆ junction box type: waterproof junction box
◆ installation method: movable flange type
◆ diameter of protective tube: 16mm, 20mm
◆ protective tube material: stainless steel 304, 321, 316, 2520, etc
◆ insertion depth of protective tube: l=150-1800mm
◆ thermal response time: t0.5<80s (when the temperature changes in steps, the output of the thermocouple changes to 50% of the change, the time required is called thermal response time, which is expressed by t0.5)
◆ nominal pressure of thermocouple: normal pressure (generally refers to the static external pressure that the protective tube can withstand without cracking at room temperature)
◆ nominal flow rate of thermocouple: 0 m / S
◆ insulation resistance of thermocouple: the test voltage of insulation resistance at room temperature is DC 500V ± 50V, the atmospheric conditions are temperature 15~35 ℃, relative humidity 45%, atmospheric pressure 86~106kpa, and its insulation value at room temperature should be ≥ 100m Ω.
◆ executive standard: jb/t9238-1999
Product working principle of Movable flange thermocouple
When there are two different conductors, and their two ends are welded with each other, the temperature at the two nodes is different. The temperature at one end is the measuring end or working end, and the temperature at the other end is the free end or cold end. When there is a temperature difference between the two ends, thermal current will be generated in the loop. Equipped with a display instrument, the instrument can display the corresponding temperature value of the thermoelectric EMF generated by the thermocouple. The thermoelectric EMF of the thermocouple will increase with the temperature rise at the measuring end or working end. The size of the thermoelectric EMF of the thermocouple is only related to the conductor material and the temperature difference at both ends, and has nothing to do with the length and diameter of the conductor.
Model example of Movable flange thermocouple
WRN-330 refers to the assembled thermocouple with K-index movable flange, waterproof junction box and protective tube diameter of 16mm, which can be double.
WRE-330 refers to an assembled thermocouple with e-graduation movable flange, waterproof junction box and protective tube diameter of 16mm, which can be double.
WRN-320 refers to the assembled thermocouple with K-index movable flange, splash proof junction box and protective tube diameter of 16mm, which can be double.
WRE-320 refers to an assembled thermocouple with e-graduation movable flange, splash proof junction box and protective tube diameter of 16mm, which can be double.
Product installation picture of Movable flange thermocouple
Model selecting
Model |
Graduation |
Range of temperature |
Thermal response time |
Material of tube |
Diameter |
Length |
WRM-330 WRM2-330 |
N |
0~800 0~1100 |
<90s <24s |
1Cr18Ni9Ti 0Cr25Ni20 |
Φ16 |
150 200 250 300 350 400 500 750 1000 1500 2000 2150 |
WRM-330G WRM2-330G |
||||||
WRN-330 WRN2-330 |
K |
0~800 0~1100 |
<90s <24s |
1Cr18Ni9Ti 0Cr25Ni20 |
||
WRN-330G WRN2-330G |
||||||
WRE-330 WRE2-330 |
E |
0~800 |
<90s <24s |
1Cr18Ni9Ti
|
||
WRE-330G WRE2-330G |
||||||
WRC-330 WRC2-330 |
T |
0~350 |
<90s <24s |
1Cr18Ni9Ti |
||
WRC-330G WRC2-330G |
||||||
WRF-330 WRF2-330 |
J |
0~600 |
<90s <24s |
1Cr18Ni9Ti |
||
WRF-330G WRF2-330G |
||||||
WRM-331 WRM2-331 |
N
|
0~800 0~1100 |
<90s <24s |
1Cr18Ni9Ti 0Cr25Ni20 |
Φ20 |
|
WRM-331G WRM2-331G |
||||||
WRN-331 WRN2-331 |
K
|
0~800 0~1100 |
<120s <24s |
1Cr18Ni9Ti 0Cr25Ni20 |
||
WRN-331G WRN2-331G |
||||||
WRE-331 WRE2-231 |
E
|
0~800 |
<120s <24s |
1Cr18Ni9Ti |
||
WRE-331G WRE2-231G |
||||||
WRC-331 WRC2-231 |
T
|
0~350 |
<120s <24s |
1Cr18Ni9Ti |
||
WRC-331G WRC2-231G |
||||||
WRF-331 WRF2-231 |
J |
0~600 |
<120s <24s |
1Cr18Ni9Ti |
||
WRF-331G WRF2-231G |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contact: Kevin
Phone: +8615189522935
Tel: +86-517-86800063
Whatsapp: +8615189522935
Email: sales@xfmeter.com
Add: No.118 HengyangNanRoad, Jinhu County, Huaian,Jiangsu, China
We chat